Cirrus Logic CobraNet User Manual
Page 102

102
©
Copyright 2006 Cirrus Logic, Inc.
DS651PM25
CobraNet Programmer’s Reference
Management Interface Variable Reference
Name
rxMinDelay
Description
Selects a minimum additional delay imposed on the received audio. Delay is expressed in units of
isochronous cycles (1-1/3ms for standard 5-1/3ms latency mode, 2/3ms for 2-2/3ms latency mode
and 1/3ms for 1-1/3ms latency mode). This variable is designed to allow configuration of a
deterministic common delay for all CobraNet interfaces in larger network installations.
rxDelay will
never be reduced below this setting. This variable is not designed for actively delaying audio for
architectural applications. The maximum setting for
rxMinDelay is determined by the amount of
Ethernet packet buffering available on the interface. Excessive settings will result in
ERROR_RXBUFFER_OVERFLOW errors and accompanying audio dropouts.
Host Address
0x4n106 (n is 0 based receiver number)
SNMP Object ID
1.3.6.1.4.1.2680.1.1.6.1.1.9.n (n is 1 based receiver number)
Type
Integer
Attributes
Read/write - Persistent
Default Value
0
Implemented Version
2.8.3
Name
rxSubFormat
Description
Vector of received audio format for each sub-channel. See
for a complete listing
of valid format values.
The least significant bit of these variables is set when the received format is supported for reception
by the CobraNet interface. A test of this least significant bit can be used to determine correct
reception on a per audio channel basis.
All entries in this vector will be 0 if
rxStatus is zero.
Host Address
0x4n30m (n is 0 based receiver number, m is 0 based audio channel number)
Count
8
SNMP Object ID
1.3.6.1.4.1.2680.1.1.6.2.1.3.n.m (n is 1 based receiver number, m is the 1 based sub-channel
number)
Type
Integer
Attributes
Read-only
Implemented Version
2.2.0