CobraNet Programmer’s Reference

Management Interface Variable Reference

DS651PM25

©

Copyright 2006 Cirrus Logic, Inc.

39

Name

ifAdminStatus

Description

The desired state of the interface. The testing(3) state indicates that no operational packets can be
passed
up(1) -- ready to pass packets
down(0)

Host Address

0x111000

SNMP Object ID

1.3.6.1.2.1.2.2.1.7

Type

Integer

Attributes

Read/Write

Default Value

1

Implemented Version

2.1.0

Name

ifOperStatus

Description

The current operational state of the interface. The testing(3) state indicates that no operational
packets can be passed.
up(1) - ready to pass packets
down(0)

Host Address

0x112000

SNMP Object ID

1.3.6.1.2.1.2.2.1.8

Type

Integer

Attributes

Read-only

Default Value

1

Implemented Version

2.1.0

Name

ifLastChange

Description

The value of

sysUpTime at the time the interface entered its current operational state. If the current

state was entered prior to the last re- initialization of the local network management subsystem,
then this object contains a zero value.

Host Address

0x112001

SNMP Object ID

1.3.6.1.2.1.2.2.1.9

Type

TimeTicks

Attributes

Read-only

Default Value

n.a.

Implemented Version