Cirrus Logic CobraNet User Manual
Page 83

CobraNet Programmer’s Reference
Management Interface Variable Reference
DS651PM25
©
Copyright 2006 Cirrus Logic, Inc.
83
Name
bridgeRxFilter
Description
Selects which types of received packets will be passed to the host via the packet bridge. The
following values may be ORed together. See
0x1 - bridge unprocessed CobraNet packets
0x2
1
- bridge all CobraNet reservation packets
0x8
1
- bridge all IP packets (IP, ARP and RARP)
0x10 - bridge all packets with unknown protocol identifier
1
Copies of packets are passed to the packet bridge and the originals are still processed by the
CobraNet interface. Care must be taken that redundant replies are not generated.
Host Address
0x2000E
SNMP Object ID
Not available via SNMP
Type
Integer
Attributes
Read/Write
Default Value
1
Implemented Version
2.6.9
Name
bridgeTxPktBuffer
Description
Buffer for bridge packet transmission. The first word contains the length of the packet in bytes
exclusive of the length field itself. Ethernet packet data, including complete header and payload,
follows the length. The FCS field is computed and appended by the Ethernet controller and is not
included as part of the packet data or length.
See
Section 2.2 "Packet Bridge" on page 13
for more information on the format and use of this
buffer
Host Address
0x21000
SNMP Object ID
Not available via SNMP
Count
758 on 24-bit platforms, 380 on 32-bit platforms.
Type
Integer16
Attributes
Read/Write
Implemented Version
2.2.0