beautypg.com

Cirrus Logic CobraNet User Manual

Page 78

background image

78

©

Copyright 2006 Cirrus Logic, Inc.

DS651PM25

CobraNet Programmer’s Reference
Management Interface Variable Reference

Name

conductorGaps

Description

These timing specifications are applicable only to repeater networks and therfore do not apply to
most CobraNet applications. This variable is changed on the active conductor in order to reduce the
probability of collisions. In most cases the default value works well. Useful values other than the
default are dependant on the specific network topology used.
Channel Gap in LS byte - Larger channel gaps allow greater network diameter.
Packet Gap in MS byte - Larger packet gaps increase resilience to unregulated traffic.

Host Address

0x10003

SNMP Object ID

1.3.6.1.4.1.2680.1.1.4.3

Type

Integer16

Attributes

Read/write - Persistent

Default Value

0x0306

Implemented Version

2.2.0

Name

conductorStatus

Description

Conductor status:
0 - This interface is not the conductor
1 - This interface is the conductor

Host Address

0x11000

SNMP Object ID

1.3.6.1.4.1.2680.1.1.4.4

Type

Integer

Attributes

Read-only

Implemented Version

2.1.0