Management Interface Variable Reference

Name

ifmtStatus

Description

Status of Ethernet connection. The following values may be OR’d together:
1 - Ethernet link established
2 - Connection is full-duplex
4 - Ethernet packets being received at a rate of at least 1 packet every two seconds.

Host Address

0x74n00
where:
n = 0 = primary Ethernet interface
n = 1 = secondary Ethernet interface

SNMP Object ID

1.3.6.1.4.1.2680.1.1.9.3.3.1.2.n

Count

2

Type

Integer

Attributes

Read Only

Implemented Version

2.9.9 (24-bit platforms), 2.10.3 (32-bit platforms)

Name

ifmtLastChange

Description

The value of

sysUpTime at the time ifmtStatus was established. If the current state was entered

prior to or concurrent with the last re-initialization of the local network management subsystem, then
this object contains a zero value.

Host Address

0x74n01
where:
n = 0 = primary Ethernet interface
n = 1 = secondary Ethernet interface

SNMP Object ID

1.3.6.1.4.1.2680.1.1.9.3.3.1.3.n

Count

2

Type

Time Ticks

Attributes

Read Only

Implemented Version

2.9.9 (24-bit platforms), 2.10.3 (32-bit platforms)