Cirrus Logic CobraNet User Manual
Page 129

CobraNet Programmer’s Reference
Error Code Reference
DS651PM25
©
Copyright 2006 Cirrus Logic, Inc.
129
Byte
Code
Flash
Code
Type Name Description
Expected
Conditions
Unexpected
Conditions
9 3,3,1 FATAL
POST_B0M
Memory failure;
middle byte, main
bank.
-
Memory chip
problem. Data bus
problem. Address
bus problem.
10 5,3,1 FATAL
POST_B0H
Memory failure;
high byte, main
bank.
-
Memory chip
problem. Data bus
problem. Address
bus problem.
11 7,3,1 FATAL
POST_B1L
Memory failure;
low byte, high
bank.
-
Memory chip
problem. Data bus
problem. Address
bus problem.
12 1,4,1 FATAL
POST_B1M
Memory failure;
middle byte, high
bank.
-
Memory chip
problem. Data bus
problem. Address
bus problem.
13 3,4,1 FATAL
POST_B1H
Memory failure;
high byte, high
bank.
-
Memory chip
problem. Data bus
problem. Address
bus problem.
14 5,4,1 FATAL
POST_BUS
Address/data bus
test failure during
bus stress test.
-
Address and/or
data bus
performance is
marginal.
15 7,4,1 FATAL
POST_LOOPBACK
Ethernet physical
interface (PHY)
loopback test
failure. Cannot
transmit and
receive packet
correctly.
-
Problem with
Ethernet controller
(MAC or PHY).
Problem with
Ethernet DMA
(Xilinx).
16 1,5,1 FAULT
FLASH_FAILURE
Failure during flash
erase or write
operation.
Flash device has
fatigued due to
excessive
write/erase
operations.
Problem with flash
device or flash <->
DSP interface.
17 3,5,1 FAULT
FLASH_WRITE
Attempt to program
flash location
before erase.
-
Flash erase
failure.
18 5,5,1 FATAL
BAD_CONFIG
Bad configuration
record in flash
No configuration
parameters
specified during
boot bank
programming and
an existing
configuration
record could not be
found.
The configuration
record does not
match the main
code. Either the
flash is improperly
programmed or
there is a problem
with the flash bank
selection logic or
other address
decode logic.
19 7,5,1 FAULT
INT_UNEXPECTED
Interrupt occurred
while interrupts
were disabled.
- -