beautypg.com

Cirrus Logic CobraNet User Manual

Page 71

background image

CobraNet Programmer’s Reference

Management Interface Variable Reference

DS651PM25

©

Copyright 2006 Cirrus Logic, Inc.

71

Name

flashTAcknowledge

Description

A semaphore variable updated to the value of

flashTRequest on completion of a flash write.

Host Address

0x1006

SNMP Object Identifier

Not available via SNMP

Type

Integer

Attributes

Read-only

Implemented Version

2.8.6

Name

flashPersistEnable

Description

Non-zero value enables variable persistence feature.

Read/write - Persistent

type variables will be

automatically written to non-volatile memory when changed. Values will be restored on power-up.

Host Address

0x1100

SNMP Object ID

1.3.6.1.4.1.2680.1.1.2.7

Type

Integer

Attributes

Read/write - Persistent

Default Value

0

Implemented Version

2.8.1

Name

flashPersistAck

Description

Forces a write of variables to non-volatile memory when set to a non-zero value. Value returns to
zero when write has completed. This value will not change if persistence is disabled. This feature is
recommended for use during factory configuration where writing and confirmation of success must
be done in a timely manner. In normal use it is best to let the interface schedule writes to non-
volatile memory. Over-use of this feature can result in excessive wear on the flash device.

Host Address

0x1200

SNMP Object ID

1.3.6.1.4.1.2680.1.1.2.8

Type

Integer

Attributes

Read/Write

Default Value

0

Implemented Version

2.8.1