CobraNet Programmer’s Reference

Management Interface Variable Reference

DS651PM25

©

Copyright 2006 Cirrus Logic, Inc.

77

6.4.5 Conductor

These variables determine the values transmitted in the header of the Beat Packet when
the CobraNet interface is acting as the network conductor.

Name

conductorCycleRate

Description

Number of isochronous cycles per second as a 16.16 fixed point number. This is a legacy variable.
It always reports default value and should not be changed.

Host Address

0x10000

SNMP Object ID

1.3.6.1.4.1.2680.1.1.4.1

Type

Integer48

Attributes

Read/write - Persistent

Default Value

750

Implemented Version

2.2.0

Name

conductorPriority

Description

Specifies the conductor priority for a CobraNet device. The device with the highest priority will
become the conductor for the network. MS byte must be 0.
0 - Never Conduct
0x1 - Lowest conductor priority
0xFF - highest conductor priority

Host Address

0x10002

SNMP Object ID

1.3.6.1.4.1.2680.1.1.4.2

Type

Integer16

Attributes

Read/write - Persistent

Default Value

0x20 for reference design, 0x30 for CM-1, CS4961xx, and CS1810xx.

Implemented Version

2.2.0