3 mib-ii variables, 1 system – Cirrus Logic CobraNet User Manual
Page 33

CobraNet Programmer’s Reference
Management Interface Variable Reference
DS651PM25
©
Copyright 2006 Cirrus Logic, Inc.
33
6.3
MIB-II Variables
These variables are common to all SNMP implementations. This common set of
management variables is defined in the Internet Engineering Task Force (IETF) standards
document RFC 1213.
6.3.1 System
Name
sysDescr
Description
Describes type of interface as ASCII text.
Format for 24-bit platforms:
where
CS18102, CS18110, CS18111, CS18112}
Format for 32-bit platforms:
where
CS18102, CS18110, CS18111, CS18112} and
number that is part of the Cirrus part number. Example:
Cirrus Logic EV-2/CM-2 (CM18101)
CobraNet version 2.10.4 CS181012
Format for RAVE platforms:
NOTE: [.
added to the firmware by Cirrus Logic for 24-bit platforms or added by the OEM using the
CNCustom program for 32-bit platforms.
Eaxmple for CS18101: Cirrus Logic EV-2/CM-2 (CM18101) CobraNet version 2.10.5 CS181012
Host Address
0x100000
SNMP Object ID
1.3.6.1.2.1.1.1
Size
84 characters (28 * 3 bytes) for 24-bit platforms. Length was 21 words in 2.9.10. It is now 27 words.
84 characters (21 * 4 bytes) for CS4961xx- and CS1810xx-based platforms.
Type
DisplayString
Attributes
Read-only
Default Value
“[manufacturer name] [product name] CobraNet firmware [protocol version].[major version].[minor
version].[manufacturer's version (optional, see note above)]”
Implemented Version
2.6.3