beautypg.com

Error code reference, 1 legend – Cirrus Logic CobraNet User Manual

Page 126

background image

126

©

Copyright 2006 Cirrus Logic, Inc.

DS651PM25

CobraNet Programmer’s Reference
Error Code Reference

9.

Error Code Reference

9.1

Legend

Byte Code - Numeric error code. Error codes reported through SNMP or HMI are of
varying form must be converted to this common byte code representation as per
instructions give in section 9.2 below.

Flash Code - Code as reported in a fatal fault situation. Flash codes are typically only
displayed for fatal errors.

Type - Classification and behavior of the error condition.

Name - Name assigned to the error by the firmware programmer.

Description - Description of the error condition.

Expected Conditions - Foreseeable conditions under which the error condition would
occur on normally functioning and properly connected hardware.

Unexpected Conditions - Conditions indicating a hardware of firmware fault.

Table 17. Error Types

Type

Description

TX

Recoverable and expected transmit error

TXQUIET

Informative transmit incident

TXFAULT

Unexpected but recoverable transmit error

RX

Recoverable and expected receive error

RXQUIET

Informative receive incident

RXFAULT

Unexpected but recoverable receive error

TXRX

Recoverable and expected error simultaneously affecting transmit and receive

FAULT

Unexpected but recoverable error

FATAL

Unrecoverable error condition. Reported as a flash code on the fault indicator.