2 conductor priority, 3 name, 2 conductor priority 7.3 name – Cirrus Logic CobraNet User Manual
Page 123

CobraNet Programmer’s Reference
Recommended User Interface Practices
DS651PM25
©
Copyright 2006 Cirrus Logic, Inc.
123
provided. Optional user interface control of receiver functionality may include any
combination of the following:
• Audio destination channel mapping per receiver audio channel
• Bundle and request priority
7.2
Conductor Priority
It is not necessary to give users the ability to change conductor priority via a front panel
interface. If manipulation of conductor priority is desired, allowing three options with
regard to conductor priority selection is recommended:
• Never - conductorPriority = 0
• Normal - conductorPriority = 32
• High - conductorPriority = 128
7.3
Name
Users should be able to either select and display or simply display a network name for the
device. This network name is stored in the
sysName management variable as an ASCII
string that is 4 to 16 characters in length. a-z, A-Z, 0-9 and - [hyphen] are allowed
characters. Names are not case sensitive. A name may be as simple as 4 numeric
characters. A set of thumb wheel switches can be used to provide a unique numerical
name. Names containing only 0's (zeros) and "NONAME" are reserved names indicating
that no name has been assigned to the unit.