CobraNet Programmer’s Reference
Management Interface Variable Reference
6.5.2 Control
The
control variables are for control and monitoring of DSP parameters. The organization
of parameters is specific to the DSP Conductor configuration currently in force. See the
application note AN279,
“Controlling and Monitoring DSP Conductor Configurations” for
details.
Name
procFreeCycles
Description
Free CPU cycles in thousandths (1000=100.0%, 256=25.6%).
Negative values indicate inadequate free cycles.
This condition is normally accompanied by errors (advancing errorCount).
Host Address
0x75201
SNMP Object ID
1.3.6.1.4.1.2680.1.4.1.3
Type
Integer
Attributes
Read Only
Implemented Version
2.11.1
Name
controlRWLength
Description
Length of read-write control variable set instantiated in controlRWValue.
Host Address
0x75300
SNMP Object ID
1.3.6.1.4.1.2680.1.4.2.1
Type
Integer
Attributes
Read Only
Implemented Version
2.11.1
Name
controlRWValue
Description
Writable DSP parameters.
Host Address
0x76000+n (
n is the 0-based parameter offset)
SNMP Object ID
1.3.6.1.4.1.2680.1.4.2.2.1.2.n (
n is the 1-based parameter offset)
Type
Integer
Attributes
Read/Write
Default Value
DSP Conductor configuration specific.
Implemented Version
2.11.1