beautypg.com

16 ip monitor – Cirrus Logic CobraNet User Manual

Page 116

background image

116

©

Copyright 2006 Cirrus Logic, Inc.

DS651PM25

CobraNet Programmer’s Reference
Management Interface Variable Reference

6.4.16 IP Monitor

Name

ipMonCurrentIP

Description

The current IP address for the CobraNet interface. Changing the current IP address has an
immediate effect on IP communications. A value of 0.0.0.0 indicates no IP address assignment for
the interface. An IP address can be assigned (or reassigned) to the interface by any of the following
means:
A value loaded from

ipMonStaticIP during power-up.

A host processor writing to

pMonCurrentIP via the HMI.

Receipt of a BOOTP response packet (typically in response to a transmitted BOOTP request)
Receipt of a RARP response packet (RARP requests are not transmitted)

Host Address

0x72000

SNMP Object ID

1.3.6.1.4.1.2680.1.1.9.2.2

Type

IpAddress

Attributes

Read/Write

Default Value

ipMonStaticIP

Implemented Version

2.6.3

Name

ipMonStaticIP

Description

A power-up static IP address assignment for the interface. A value of 0.0.0.0 indicates no power-up
IP address assignment.

Host Address

0x72002

SNMP Object ID

1.3.6.1.4.1.2680.1.1.9.2.1

Type

IpAddress

Attributes

Read/write - Persistent

Default Value

0.0.0.0

Implemented Version

2.8.2