CobraNet Programmer’s Reference
Management Interface Variable Reference

6.4.15 MI Monitor

Name

miMonDirty

Description

Incremented when a management interface variable is modified either via SNMP or HMI. Multiple
modifications may result in a single increment of this counter. The act of writing a variable, even if
written with its current value, is considered a modification for the purposes of this counter.

Host Address

0x71000

SNMP Object ID

1.3.6.1.4.1.2680.1.1.9.1.1

Type

Counter

Attributes

Read-only

Default Value

0

Implemented Version

2.6.3 (available via SNMP in 2.6.4)

Name

miMonSNMPDirty

Description

Incremented if a management interface variable is modified through SNMP. The counter is intended
to allow detection of variable modification by any SNMP manager. Multiple modifications may result
in a single increment of this variable. The act of setting a variable, even if set to its current value, is
considered a modification for the purposes of this counter.

Host Address

0x71001

SNMP Object ID

1.3.6.1.4.1.2680.1.1.9.1.2

Type

Counter

Attributes

Read-only

Default Value

0

Implemented Version

2.6.5

Name

miMonHMIDirty

Description

Incremented if a management interface variable is modified through HMI. The counter is intended to
allow detection of variable modification by a local manager. Multiple modifications may result in a
single increment of this variable. The act of writing a variable, even if written with its current value, is
considered a modification for the purposes of this counter.

Host Address

0x71002

SNMP Object ID

1.3.6.1.4.1.2680.1.1.9.1.3

Type

Counter

Attributes

Read-only

Default Value

0

Implemented Version

2.6.5