6.4.13 Synchronization

Name

syncConductorClock

Description

Selects sample clock source when acting as network conductor.
0x0 - Internal mode.
0x1 - External Word Clock mode.
0x10 - Not supported on CobraNet

Silicon Series devices. (Internal with External Sample

Synchronization mode.)
0x14 - Not supported on CobraNet

Silicon Series devices. (External Master Clock with External

Sample Synchronization mode.)

Host Address

0x60000

SNMP Object ID

1.3.6.1.4.1.2680.1.1.8.1

Type

Integer

Attributes

Read/write - Persistent

Default Value

0

Implemented Version

2.2.1

Name

syncPerformerClock

Description

Selects sample clock source when acting as a performer. Values are the same as documented
above for

syncConductorClock. External clocks applied must be externally synchronized to the

conductor.

Host Address

0x60001

SNMP Object ID

1.3.6.1.4.1.2680.1.1.8.2

Type

Integer

Attributes

Read/write - Persistent

Default Value

0

Implemented Version

2.2.1