Verify apdu (programmable security code) – MagTek IntelliStripe65 99875161 User Manual
Page 95

Appendix B. Memory Card Support
89
CLA
INS
P1
P2
Lc
Data Field
D0
D8
Adr1
Adr0
Len
Data to be written
CLA is always D0
INS is always D8
P1 is upper byte of address to write and must not be greater than ‘03’
P2 is lower byte of address to write.
Lc is the number of bytes to write, 0-1024
Data Field contains the bytes to write. If a byte to be written is already protected, a status
6581 will be returned. Data is written first, then the Protect bit is written with
comparison, assuring that the data being protected is the data you wanted to
protect.
Response APDU:
SW1
SW2
Possible SW1/SW2 combinations:
SW1/SW2
Meaning
9000
Normal completion, no errors
6581
Memory Failure, some bytes were not written
6B00
Offset outside of the Memory (Combination of P2 and Lc is invalid)
Verify APDU (Programmable Security Code)
Because of card functionality, this APDU should not be sent until at least one Read Binary
APDU has been sent first.
Command APDU:
CLA
INS
P1
P2
Lc
Data Field
00
20
00
00
Len
Data to be verified
CLA is always 00
INS is always 20
P1 is 00
P2 is 00
Lc is the number of bytes for verification:
If the value is 00, the status 63Cx will be returned where x indicates the number
of further retries allowed. This mode does not
If the value is the one less than the value of Property A7, the PSC contained in the
Data Field will be presented for verification.
use up an attempt!
Response APDU:
SW1