Power down command, T=0 error / warning condition templates – MagTek IntelliStripe65 99875161 User Manual
Page 48

IntelliStripe 65 Command Reference
42
Example Response:
Field
MTYP
APPL
CMND
RC
DATA
Byte
1
2
3
4
5-8
Value (Hex)
40
02
80
00
3B 60 00 00
POWER DOWN COMMAND
Command ID: 81 (Hex)
Description:
This command is used to power down a smart card in the currently selected connector.
Request Message Data: None
Response Message Data: None
Response Message Result Codes
Code Meaning
00
Success.
Example Request:
Field
MTYP
APPL
CMND
RC
Byte
1
2
3
4
Value (Hex)
00
02
81
00
Example Response:
Field
MTYP
APPL
CMND
RC
Byte
1
2
3
4
Value (Hex)
40
02
81
00
T=0 ERROR / WARNING CONDITION TEMPLATES
Byte
Bit
Meaning
0
0
Timeout On Receive. This condition indicates a receive timeout.
0
1
Unrecoverable Receive Error. This condition indicates a receive error
that could not be corrected by the permitted number of parity
correction retries.
0
2
Invalid Procedure Byte received from card.
0
3
Unrecoverable Transmit Error. This condition indicates a transmit
error that could not be corrected by the permitted number of parity
correction retries.
0
4-7 Reserved for Future Use
1-3
All
Reserved for Future Use