Section 4. Magnetic Stripe Application
17
DECODE JIS TYPE 2 PROPERTY
Property ID: 15 (Hex)
Property Type: Boolean
Power Up/Reset Value: 0 (False)
Get/Set/Save support: All
Description:
If this property is set to true then cards encoded to JIS X 6302 type 2 standards can be decoded.
Values:
Value
Decode JIS Type 2
0
False
1
True
Example Set Property Request:
Field
MTYP
APPL
CMND
RC
PTYP
PID
PVAL
Byte
1
2
3
4
5
6
7
Value (Hex)
00
01
01
00
03
15
01 (True)
Example Set Property Response:
Field
MTYP
APPL
CMND
RC
Byte
1
2
3
4
Value (Hex)
40
01
01
00
CLEAR DATA COMMAND
Command ID: 80 (Hex)
Description:
This command is used to clear all magnetic stripe data so that the data can no longer be acquired
from the device. After this command is issued, no magnetic stripe data will be available until a
card is read.
After a card is read, the magnetic stripe data is held in the device until:
1.
Another card read occurs.
2.
A Clear Data command is issued.
3.
The device is power cycled or reset.
Request Message Data: None
Response Message Data: None
Response Message Result Codes:
Success = 00 (Hex)
The command completed successfully.