Update binary apdu, Update binary with protection apdu – MagTek IntelliStripe65 99875161 User Manual
Page 94

IntelliStripe 65 Command Reference
88
Response APDU:
Data Field (from card)
SW1
SW2
Data indicates the protection status for the byte located at the corresponding address on the card.
The value ‘00’ indicates the location is protected and cannot be updated. A value ‘01’ indicates
the location is not protected and can be updated.
Possible SW1/SW2 combinations:
SW1/SW2
Meaning
9000
Normal completion, no errors
6B00
Offset outside of the Memory (Combination of P2 and Le is invalid)
Update Binary APDU
Because of card functionality, this APDU should not be sent until at least one Read Binary
APDU has been sent first.
Command APDU:
CLA
INS
P1
P2
Lc
Data Field
00
D6
Adr1
Adr0
Len
Data to be written
CLA is always 00
INS is always D6
P1 is upper byte of address to write and must not be greater than ‘03’
P2 is lower byte of address to write.
Lc is the number of bytes to write, 0-1024
Data Field contains the bytes to write. If a byte to be written is already protected, a status
6581 will be returned.
Response APDU:
SW1
SW2
Possible SW1/SW2 combinations:
SW1/SW2
Meaning
9000
Normal completion, no errors
6581
Memory Failure, some bytes were not written
6B00
Offset outside of the Memory (Combination of P2 and Lc is invalid)
Update Binary With Protection APDU
Because of card functionality, this APDU should not be sent until at least one Read Binary
APDU has been sent first.
This APDU will not be found in ISO 7816-4. That is why it has the CLA of D0 (Proprietary).
Command APDU: