Notify indicator change 0 to 1 property – MagTek IntelliStripe65 99875161 User Manual
Page 59

Section 7. Transport Application
53
Example Get Property Response:
Field
MTYP
APPL
CMND
RC
PTYP
PID
Byte
1
2
3
4
5
6
Value (Hex)
40
82
00
00
01
00
Field
PVAL
Byte
7 - 10
Value (Hex)
07 00 00 00 (Card is present, seated and latched)
NOTIFY INDICATOR CHANGE 0 TO 1 PROPERTY
Property ID: 01 (Hex)
Property Type: Dword
Power Up/Reset Value: 0
Get/Set/Save support: All
Description:
This property is used control notification messages sent in response to a transport indicator
changing from a 0 to a 1 state. If the bit corresponding to an indicator is set then, a notification
message will be sent from the device to the host in response to that indicator changing from a 0
to a 1 state. The notification message will have the same syntax as the get property command
response of the indicator property. The only difference is that the message header will contain a
notification message type instead of a response message type. If more than one indicator
changes state at the same time, only one notification message will be sent that contains the state
of all the indicators.
Values:
The bits are identified by numbering the least significant bit 0 and the most significant bit 31.
Bits
Indicator
Description
0
Card Present
If set to 1 a notification message will be sent in response to a
0 to 1 transition of the card present indicator. If cleared to 0,
no notification will be sent.
1
Card Seated
If set to 1 a notification message will be sent in response to a
0 to 1 transition of the card seated indicator. If cleared to 0,
no notification will be sent.
2 – 6
RFU
Reserved for future use
7
*MagnePrint Noise If set to 1 a notification message will be sent in response to a
0 to 1 transition of the MagnePrint™ noise indicator. If
cleared to 0, no notification will be sent.
8-31
RFU
Reserved for future use
* Available only on units with MagnePrint feature