MagTek IntelliStripe65 99875161 User Manual
Page 42

IntelliStripe 65 Command Reference
36
Initial T=1 Warning
Conditions
Template
74
Binary
4
(Hex)*
3E F4 9E
00
Get/Set Used to define which conditions shall be considered warnings when
running with the T=1 protocol. See Error / Warning Condition Templates
for further discussion. See T=1 Error / Warning Conditions for specific
coding.
Initial Use EMV
NAD Rules
75
Boolean
1
FALSE*
Get/Set TRUE indicates to validate NAD according to EMV rules. FALSE
indicates to ignore NAD received from cards. In EMV Mode this property
is TRUE.
IFSD Allowed after
ATR
76
Boolean
1
TRUE*
Get/Set TRUE indicates an S(Req IFSD(254)) should be sent to the card after the
ATR has been received. FALSE indicates no S(Req IFSD) should be
sent. In all cases, the effective IFSD is 254 as the IFD always accepts
full length messages.
T=1 Microprocessor Card Operating Properties, used to control the T=1 protocol operations. Settings of these properties only apply to the current
card session.
Actual NAD
88
Binary
1
0x00*
Get/Set This is the NAD byte per ISO 7816-3(1997).
Actual CWT
89
Dword
2
N/A
Get
This is the current CWT, in units of 2 ms, calculated per ISO 7816-
3(1997).
Actual BWT
8A
Dword
2
N/A
Get
This is the current BWT, in units of 2 ms, calculated per ISO 7816-
3(1997).
Actual EDC
8B
Binary
1
N/A
Get
This is the EDC indicator per ISO 7816-3(1997).
Current Session
Resynch Allowed
8C
Boolean
1
N/A
Get/Set Similar to the Initial Resynch Allowed property, but applies to the current
session only.
Current Chaining
Allowed
8D
Boolean
1
N/A
Get/Set Similar to the Initial Chaining Allowed proprety, but applies to the current
session only.
Current IFSC
8E
Dword
1
N/A
Get
The IFSC in use for the current session.
Current Output
Sequence Number
8F
Dword
1
N/A
Get
This is the sequence number of the next I-block that will be sent to the
card.
Current Input
Sequence Number
90
Dword
1
N/A
Get
This is the sequence number expected in the next I-block that will be
received from the card.
Current T=1 Error
Conditions
Template
91
Binary
4
N/A*
Get/Set Used to define which conditions shall be considered errors when running
with the T=1 protocol. See Error / Warning Condition Templates for
further discussion. See T=1 Error / Warning Conditions for specific
coding. The values are initialized from the Initial T=1 Error Conditions
Template property.