AMETEK 2110 Shut Height Monitor User Manual
Page 56
Installation and Programming Manual
52
Appendix A: Error Messages
53
Installation and Programming Manual
Appendix A: Error Messages
The following chart contains errors that will cause the fault check relay to open:
Chart A-4 Fault Check Relay Errors
Error Displayed
Error Description
Solution
EEr 1
An invalid function number was
entered.
Enter a valid function number.
EEr 2
An invalid system configuration was
entered.
Enter a valid system configuration.
EEr 3
A value outside the function's ac-
ceptable range was entered.
Review function's range and re-en-
ter value.
EEr 4
An incorrect parameter was entered. Contact GEMCO Tech. Support.
EEr 5
A value was programmed into the
Lower End Limit function that is
greater than the value programmed
in the Upper End Limit function.
Program a value that is less than
the value programmed in the Upper
End Limit function.
EEr 6
The value programmed into the Up-
per End Limit function is less than
the value programmed in the Lower
End Limit function.
Program a value that is greater than
the value programmed in the Lower
End Limit function.
Chart A-3: Entry Errors
Error Displayed
Error Description
SEr101
A configuration error occurred.
SEr106
Firmware CRC error occurred.
SEr320
This is resolver-specific error. See Chart A-6.
SEr330
The input device is not connected to the monitor's input module.
SEr331
This is an LDT-Specific Error. See Chart A-7.
OEr101
The press's ram did not move within the time programmed in the Move
Detection Time-out function.
OEr330 or
OEr320
The press's shut height moved beyond the value programmed in the Nega-
tive Over Travel Limit function.
T13692 appendix a.indd
3/17/04, 6:54 AM
52