AMETEK 2110 Shut Height Monitor User Manual
Page 40
![background image](/manuals/409779/40/background.png)
Installation and Programming Manual
36
Chapter 4: Programming
37
Installation and Programming Manual
Chapter 4: Programming
4. The default value for the Move Detection Time-Out function is 5.00 seconds.
To change this value for the position hold dwell time, select the function key.
The monitor displays “F-----”
5. Enter function number 12. Select the enter key.
The monitor displays the current value for the position hold dwell time. This
value is in seconds.
6. Select the new dwell time. Select the enter key.
NOTE: The Position Hold function only holds the position on the monitor’s LED display.
Internally, the shut height position and the upper and lower limit relays are continually
being updated. In addition, the auxiliary LED can be used to determine when a position
hold occurs. However, this LED must be selected for this feature. To enable this LED,
see Auxiliary LED.
Auxiliary LED (16)
The Auxiliary LED function is used to enable the monitor’s auxiliary LED. This LED is
currently used only to indicate a position hold. (For more information, see Position Hold). Either
a 0 or 1 can be programmed in this function. Entering a 0 will disable the LED. Entering a 1 will
enable the LED to turn on when a position hold occurs. The default for this function is 0. To
enable or disable the auxiliary LED, perform the following steps:
1. Select the function key.
The monitor displays “F-----”
2. Select function number 16. Select the enter key.
The monitor displays the function’s current value.
3. Enter either 0 or 1. Select the enter key.
Enter new
dwell value
12
Enter either 0
or 1
16
(F)
8
8
(F)
8
8
T13692 Chapter 4.indd
3/17/04, 6:50 AM
36