Chapter 7 __________________________________________________ Getting the Data Messages
VAISALA_______________________________________________________________________ 89
Example 2:
Start a concurrent pressure, humidity and temperature measurement and
request the data:
0C2!000503
parameters available, for aC command device address not sent as a sign
of a completed measurement)
0D0!0+23.6+29.5+1009.5
Example 3:
Start a precipitation measurement and request the data:
0M3!00006
device address is not sent)
0D0!0+0.15+20+0.0+0.0+0+0.0
Example 4:
Start a supervisor measurement with CRC and request the data:
0MC5!00014
parameters available)
0
0D0!0+34.3+10.5+10.7+3.366DpD
Example 5:
Start a composite measurement and request the data. The configuration
of the parameter set is such that nine (9) parameters are available. Thus
start measurement command aM can be used. Due to the 35-character
limit in response message, aD0 returns only six parameters. The
remaining parameters are retrieved with aD1.
0M!00059
parameters available)
0
0D0!0+340+0.1+23.7+27.9+1009.3+0.15
0D1!0+0.0+0+0.0