Pressure, temperature, and humidity sensors, Checking the settings (atu), Pressure, temperature, and – Vaisala WXT520 User Manual
Page 115

Chapter 8 ____________________________________________ Sensor and Data Message Settings
VAISALA______________________________________________________________________ 113
Pressure, Temperature, and Humidity Sensors
Checking the Settings (aTU)
With this command you can check the current pressure, temperature and
humidity sensor settings.
Command format in ASCII and NMEA 0183: aTU
Command format in SDI-12: aXTU!
The response in ASCII and NMEA 0183:
aTU,R=[R],I=[I],P=[P],H=[H]
The response in SDI-12:
aXTU,R=[R],I=[I],P=[P],H=[H]
where [R][I][P][H] are the setting fields, see the following section.
Example (ASCII and NMEA 0183, device address 0):
0TU
0TU,R=11010000&11010000,I=60,P=H,T=C
Example (SDI-12, device address 0):
0XTU!0XTU,R=11010000&11010000,I=60,P=H,T=C
where
a
=
Device address
TU
=
Pressure, temperature and humidity sensor settings
command in ASCII and NMEA 0183
XTU
=
Pressure, temperature and humidity sensor settings
command in SDI-12
=
Command terminator in ASCII and NMEA 0183
!
=
Command terminator in SDI-12