Figure 32, Wind measurement averaging method, Case 1 case 2 case 3 – Vaisala WXT520 User Manual
Page 166

User’s Guide ______________________________________________________________________
164 _________________________________________________________________ M210906EN-C
0505-215
Figure 32
Wind Measurement Averaging Method
I
I
A
A
time
1 sec
time
1 sec
...
...
I > A, all communication p rotocols other than SDI-12 (aXU,M=S). In this example I=5 sec and A=3 sec.
I < A, all communication p rotocols other than SDI-12 (aXU,M=S). In this example I=2 sec and A=5 sec.
I
I
I
I
...
...
A
A
A
A
A
time
1 sec
...
Communication protocol SDI-12 (aXU,M=S). In this example A=3 sec. I does not have any function in this protocol.
Issuing
measurement
command
Data
ready
A
Issuing
measurement
command
Data
ready
...
Case 1
Case 2
Case 3