Communication setting commands, Checking the current communication settings (axu), Program, see section – Vaisala WXT520 User Manual
Page 62

User’s Guide ______________________________________________________________________
60 __________________________________________________________________ M210906EN-C
Communication Setting Commands
Checking the Current
Communication Settings (aXU)
With this command you can request the current communication settings
of WXT520.
Command format in ASCII and NMEA 0183: aXU
Command format in SDI-12: aXXU!
Example response in ASCII and NMEA 0183:
aXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]
Example response in SDI-12:
aXXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]
NOTE
Hereafter the commands to be typed are presented in normal text while
the responses of the transmitter are presented in italic.
where
a
=
Device address, which may consist of the following
characters: 0 (default) ... 9, A ... Z, a ... z.
XU
=
Device settings command in ASCII and NMEA 0183
XXU
=
Device settings command in SDI-12
=
Command terminator in ASCII and NMEA 0183
!
=
Command terminator in SDI-12
NOTE
You can add the Id information field in the supervisor data message to
provide identifying information in addition to the transmitter address.
See section
Supervisor Message on page 123
. The information field is
set as part of the factory settings (see
). You can only modify it using the Vaisala Configuration Tool.