Cellular modems, Table 102, Com server unit environmental specifications – Vaisala Hydromet Data Collection Platform User Manual
Page 377: Table 103, Gsm terminal tc35i specifications

Appendix A _____________________________________ Configuration Information for Legacy Items
VAISALA______________________________________________________________________ 375
Cellular Modems
Table 102
COM Server Unit Environmental Specifications
Property
Description/Value
Operating temperature
-40 °C ... +55 °C (-40 ... +131 °F)
Storage temperature
-60 °C ... +75 °C (-76 ... +167 °F)
Humidity
5 to 95 % RH, non-condensing
EMC
EN 55022
Immunity
ESD
EN 61000-4-2, contact dis. 4kV, air dis. 8kV
RF field
EN 61000-4-3
Fast transient bursts (EFT) EN 61000-4-4
Transient surges
EN 61000-4-5
Conducted RF
EN 61000-4-6
Vibration
IEC 68-2-64 Fh, 10 ... 500 Hz, up to 2.0 G
Free fall
IEC 68-2-32 Ed, fall height 1000 mm
Cold
IEC 68-2-1, -40 °C 16 hours
Heat
IEC 68-2-2, +55 °C 16 hours
Slow change of
temperature, 1°C/min
IEC 68-2-14, -40 °C ... +55 °C, two cycles
Table 103
GSM Terminal TC35i Specifications
Property
Description/Value
Sensitivity
-104 dBm
Dual Band
EGSM900/GSM1800
Data transmission
CSD up to 14.4.kbps
USSD
Non transparent mode
V.110
7E1-character framing
SMS
Included
Tx power
2 W (class 4)
1 W (class 1)
Supply voltage
8 ... 30 V
Power consumption
Transmit mode
300 mA (average)
Idle mode
10 mA
Sleep
3 mA
Power down
0.1 mA
Temperature range
-20 ... +55 °C
Weight
130 g (4.6 oz.)