Command example, Table 25 remote maintenance commands (continued) – Vaisala Hydromet Data Collection Platform User Manual
Page 202

User's Guide ______________________________________________________________________
200 _________________________________________________________________ M210933EN-C
Command example:
spset my_setting "This is a string with spaces"
spclear my_setting
ctev 15 60
warnings clear
lastval Instant rep 0
do TAMeasQMH101_1 TA
usermsg this has no meaning
log L0 030703120000 5
reset
Resetting the
device
n/a, not even OK.
ctev <tevID><interval> [P]
Changing the
timer interval
Timer id from Lizard
information view.
Interval in [s].
P to preserve the
parameters over reset
n/a
errors [clear] warnings [clear] Reading or
clearing a
warning or error
logs
No parameters to read
errors or warnings.
Clear to clear errors or
warnings
Example return value for
the log readout Cnt: 1
Src:idle.cpp(73) - Cnt:
number of occurrences -
Src: source file - (nn):
source file line number.
Indications are separated
with commas.
lastval <comp> <param>
<status>
Reading of the
application
variable
Component name
Variable name
The status value
included to output,
0=no, 1=yes
Value with the optional
status as listed in the
sensor status list.
do <comp> <action>
Executing an
action, for
example, a
measurement
Component name
Action identifier
n/a
usermsg
User message
without any
action
n/a
log <group> <starttime>
<records | endtime>
3
Reading set of
logged data
Loggroup Ln
Starttime in
YYMMDDhhmmss
Number of records or
end time
Logged data from single
group split into one row
per record. Values only,
no header data.
1. <> = Parameter is compulsory
2. [ ] = Parameter is optional
3. | = Parameters are alternatives
Table 25
Remote Maintenance Commands (Continued)
Command
Use
Parameters
Output