Assemble the Plates and Studs

To assemble the plates and studs, you will need the cover plate assembly as well
as the flat plate and close plate with sensor, three #8 x 5” threaded studs with
attached #8 push nuts, three #8 flat washers, three #8 split lock washers, and three
wing nuts.
1. Slide each of the three #8 x 5” (127 mm) threaded studs, with push nuts

installed, through each of the three holes in the closed plate, flat plate, support
plate, and cover plate.
When inserting the threaded studs, make sure the short end (when measured
from the push nut) goes through the plates. Screw the short end of the
threaded stud in until the cupped side of the push nut bottoms inside the recess
of the closed sensor plate. Tighten as much as you can by hand.

2. Place the plates and studs assembly aside and proceed to the appropriate

instruction for your installation.

If you are attaching your radiation shield to the SIDE of a post or a wall,
continue to "If you are attaching the radiation shield to the side of a post or
to a wall or a pipe:" (page 7).

If you are attaching your radiation shield to the TOP of a post, continue to"If
you are attaching the radiation shield to the top of a post:" (page 8).