beautypg.com

3&rqyhuvlrq,qvwuxfwlrqv – GE PGP990SENSS User Manual

Page 33

background image

33

/3&RQYHUVLRQ,QVWUXFWLRQV

$'-8677+(/2:)/$0(6,00(5

6(77,1*

The top burner valves have low flame/simmer

adjustment screws, accessible through the

valve switches. A small, thin-blade screwdriver

(approximately 1/8” blade width) is needed to access

the screw.

A

Light two other burners and set the knobs to a

medium to high setting.

B

Light the burner to be adjusted and turn the knob to

/2 or 6,00(5

C

To make adjustment, remove the control knobs. Insert

a screwdriver through the access hole in the valve

switch. Engage the adjustment screw in the valve.

If the flames were too

small or fluttered, open

the valve more than the

original setting.

If the flames are too large,

close the valve more than

the original setting.

D

Make the adjustment by

slowly turning the screw

until the flame appearance is correct. For the left side,

install the grill burner for the adjustment. The left side

cannot be turned down as low as the right side if the

grill burner is to be used.

$GMXVWWKHORZIODPHVHWWLQJXVLQJWKHYDOYHE\SDVV

VFUHZDVIROORZV

Low setting adjustments must be made with two other

burners in operation on a medium setting. This prevents

the low flame from being set too low, resulting in the

flame being extinguished when other burners are turned

on.

E

7HVWLQJ)ODPH6WDELOLW\

Test 1: Turn the knob from+,to /2 or 6,00(5

quickly. If the /2 or 6,00(5 flame goes out,

increase the flame size and test again.

Test 2: With the burner on the /2 or 6,00(5 setting,

open and close the cabinet door under the

cooktop. If the flame is extinguished by the

air currents created by the door movement,

increase the flame height and test again.

Test 3: With the burner on the /2 or 6,00(5 setting,

turn the downdraft vent fan to the +, position.

If the flame is extinguished by the air currents

created by the downdraft vent fan, increase

the flame size and test again.

5

&219(57,1*%$&.721$785$/*$6

To convert the cooktop back to natural gas, reverse the

steps taken to convert to LP.

Once the conversion is complete and checked OK, fill

out the LP sticker and include your name, organization

and date conversion was made. Apply the sticker near

the cooktop gas inlet opening to alert others in the

future that this appliance has been converted to LP

gas. If converting back to natural gas from LP, please

remove the sticker so others know the appliance is set

to use natural gas.

127( For operation at elevations above 5000 ft. (1500

m), equipment ratings shall be reduced at a rate of

2% for each 1000 ft. (300 m) above sea level before

selecting appropriately sized equipment, i.e.: Use

smaller orifices.

1DWXUDO*DVµ:&3

%XUQHU2XWSXW5DWLQJLQ%78+5

/RFDWLRQ

%78V

2ULILFH6L]H

(QJUDYLQJ

Left Rear (LR)

10,000

.0550

NAT

Left Front (LF)

10,000

.0550

NAT

Right Rear (RR)

10,000

.0550

NAT

Right Front (RF) 10,000

.0550

NAT

$'-8677+(/2:)/$0(6,00(5

6(77,1*

FRQW

)

)ODPH5HFKHFN

Repeat the adjustment for each burner. After the

adjustment is made, turn all burners off. Ignite

each burner individually. Observe the flame at the
+,position. Rotate the valve to the /2 or 6,00(5

position and be sure that the flame size decreases

as the valve is rotated counterclockwise.

5

6