The cooktop has been design-certified by CSA International. As with

any appliance using gas and generating heat, there are certain

safety precautions you should follow. You’ll find these precautions in

the Important Safety Instuctions section in the front of this Owner’s

Manual. Read them carefully.

• Be sure your cooktop is installed properly by a qualified installer or

service technician.

• The cooktop must be electrically grounded in accordance with

local codes, or in their absence, with the National Electrical Code
$16,1)3$1R³/DWHVW(GLWLRQ

• Installation of this cooktop must conform with local codes, or in

the absence of local codes, with the National Fuel Gas Code ANSI
=1)3$³/DWHVW(GLWLRQ

• Improper installation, adjustment, alteration, service or

maintenance can cause injury or property damage. Refer to

this manual. For assistance or additional information, consult a

qualified installer, service agency, manufacturer (dealer) or the gas

supplier.

• Disconnect electrical supply before servicing.
• Never reuse old flexible connectors. The use of old flexible

connectors can cause gas leaks and personal injury. Always use
1(:flexible connectors when installing a gas appliance.

• Make sure the wall coverings around the cooktop can withstand

KHDWJHQHUDWHGE\WKHFRRNWRSXSWRƒ)

• Avoid placing cabinets above the cooktop.
• If cabinets are placed above the cooktop, allow a minimum

clearance of 30” between the cooking surface and the bottom of

protected cabinets.

• A non-combustible material must be installed on the under side of

the cabinet. Use a flame retardant millboard at least 1/4” (6.3 mm)

thick, or gypsum board at least 3/16” (4.7 mm) thick, covered with

28 gauge sheet steel or 0.020” (.5 mm) thick copper. The maximum

depth of cabinets above the cooktop is 13” (33 cm).

• An air curtain or other overhead range hood , which operates by

blowing a downward airflow onto a range, shall not be used in

conjunction with a gas range unless the hood and range have

been designed, and tested in accordance with ANSI Z 21.1 and

listed by an independent testing laboratory for combination use.

• Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment

to prevent back drafting. Follow the heating equipment

manufacturer’s guideline and safety standards such as those

published by the National Fire Protection Association (NFPA),

and the American Society for Heating, Refrigeration and Air

Conditioning Engineers (ASHRAE), and the local code authorities.

When applicable, install any makeup (replacement) air system

in accordance with local building code requirements. Visit
*($SSOLDQFHVFRP for available makeup air solutions.

)25<2856$)(7<

,I

2SHQZLQGRZV
'RQ·WWRXFKDQ\HOHFWULFDOVZLWFKHV
([WLQJXLVKDQ\RSHQIODPH
,PPHGLDWHO\FDOO\RXUJDVVXSSOLHU
'RQRWVWRUHRUXVHJDVROLQHRURWKHUIODPPDEOHYDSRUV
DQGOLTXLGVLQWKHYLFLQLW\RIWKLVRUDQ\RWKHUDSSOLDQFH

,QVWDOODWLRQ

Gas Downdraft Cooktop

,QVWUXFWLRQV

If you have questions, call 800.GE.CARES (800.432.2737)

or visit our Website at:

GEAppliances.com

B()25(<28%(*,1

5HDGWKHVHLQVWUXFWLRQVFRPSOHWHO\DQGFDUHIXOO\

,03257$17

Save these instructions

for local inspector’s use.

,03257$17

Observe all governing

FRGHVDQGRUGLQDQFHV

1RWHWR,QVWDOOHU

Be sure to leave these

instructions with the Consumer.

1RWHWR&RQVXPHU

Keep these instructions for

future reference.

• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not

covered under the Warranty.

:$51,1*

Before beginning the

installation, switch power off at the service panel and

lock the service disconnecting means to prevent power

from being switched on accidentally. When the service

disconnecting means cannot be locked, securely fasten

a prominent warning device, such as a tag, to the

service panel.

,QWKH&RPPRQZHDOWKRI0DVVDFKXVHWWV

This product must be installed by a licensed plumber or

gas fitter.

When using ball-type gas shut-off valves, they shall be

the T-handle type.

A flexible gas connector, when used, must not exceed 3

feet.

18