beautypg.com

Qvwdoodwlrq,qvwuxfwlrqv – GE PGP990SENSS User Manual

Page 27

background image

,167$//7+(35(6685(

5(*8/$725$1'&211(&7

• For all connections, use a pipe sealant approved

by local codes and resistant to the activity of L.P.

gas.

• Install the pressure regulator in the gas line

as close to the cooktop inlet as possible to allow

clearance for ventilation ducting.

• Make sure the arrow on the body of the

regulator is pointing straight up and toward the

cooktop. Any other position will affect the output

pressure of the regulator. This arrow indicates correct

gas flow direction.

• Install a manual gas line shut-off valve in an

easily accessible location.

,QVWDOODWLRQ,QVWUXFWLRQV

,167$//7+(&22.723

35(3$5(7+(&22.723

FRQW

Remove the blank 9-pin connector plug from the

9-pin receptacle on the bottom of the cooktop

and discard. Connect the 9-pin plug on the blower

assembly to the matching 9-pin receptacle on the

bottom of the cooktop. Secure the connector cover

to the cooktop using 3 screws, making sure the

power cord comes out the U-shaped opening with

the wires to the motor.

9-pin

connectors

Connector

cover

27

11

Regulator

Union

Solid piping or

flexible connector

Pipe stub

Shut-off

valve

Solid piping

or flexible connector

,167$//7+(35(6685(

5(*8/$725$1'&211(&7

FRQW

127( Instead of using solid piping to connect to

the pressure regulator, an approved flexible metal

appliance connector may be used between the

shut-off valve and the pressure regulator,if local

codes permit.

Appropriate flare nuts and adapters are required

at each end of the flexible connector.

Make sure all the knobs are in the off position.

Hook up the gas line and check for leaks.

7(67)25/($.6

:$51,1*

'212786($)/$0(72

&+(&.)25*$6/($.6Do not use the cooktop until

all connections have been leak tested.
3HUIRUPOHDNWHVWSHUWKHIROORZLQJLQVWUXFWLRQV

Purchase a liquid leak detector or prepare a soap

solution of one part water, one part liquid detergent.

2. When all connections have been made, make sure

all cooktop controls are turned to 2)) and turn the

gas supply valve to 21

3. Apply the liquid leak detector or the soap solution

around all connections from the shut-off valve to

the cooktop.

A leak is identified by a flow of bubbles from the

area of the leak.

If a leak is detected, turn the gas supply RII Tighten

the fitting. Turn the gas on and test again.

1.

If the leak persists, turn the gas supply off and

contact your dealer for assistance. Do not attempt

to operate the cooktop if a leak is present.

,03257$17 Disconnect the cooktop and the

individual shut-off valve from the gas supply

piping system during any pressure testing of that

system at test pressures greater than 1/2 psig.

Isolate the cooktop from the gas supply piping

system by closing the individual manual shut-off

valve to the cooktop during any pressure testing

of the gas supply piping system at test pressures

equal to or less than 1/2 psig.

11