beautypg.com

3&rqyhuvlrq,qvwuxfwlrqv – GE PGP990SENSS User Manual

Page 31

background image

31

/3&RQYHUVLRQ,QVWUXFWLRQV

• With the installation of this conversion kit, the

cooktop should operate on LP gas at 10” of water

column pressure.

• The pressure regulator must be connected in series

with the manifold of the cooktop and must remain in

series with the supply line. For proper operation, the

maximum inlet pressure to the regulator must be no

more than 14” water column pressure for LP gas.

• When checking the regulator, the inlet pressure

must be at least 1” greater than the regulator output

setting. If the regulator is set for 10” of water column

pressure, the inlet pressure must be at least 11”.

,03257$17²

Disconnect the cooktop and

the individual shut-off valve from the gas supply piping

system during any pressure testing of that system at test

pressures greater than 1/2 psig. Isolate the cooktop from

the gas supply piping system by closing the individual

manual shut-off valve to the cooktop during any pressure

testing of the gas supply piping system at test pressures

equal to or greater than 1/2 psig.

*$66833/<

BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT THE

SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL SUPPLY

FROM THE COOKTOP.

78512))*$6$1'
(/(&75,&6833/<

&219(577+(35(6685(5(*8/$725

A

Locate the pressure regulator under the front of the

cooktop.

1

B

Remove the nut from the pressure regulator with an

adjustable wrench.

C

Twist and remove the conversion plug from the inside

of the nut. Flip the conversion plug over; then insert,

twist and lock it back into place in the nut.

D

Reinstall the nut onto the regulator.

E

Apply the LP Conversion label next to the Rating

Plate.

Shut-off valve

Electrical supply

Nut

Natural gas

LP gas

Nut

Natural gas

LP gas