Alarm modifiers and messages, Extended data, Ovl alarm cli commands – HP e-Commerce Server Accelerator sa7120 User Manual
Page 127: Nls: network link status alarm
C H A P T E R 7
Alarm Types
117
Alarm Modifiers and Messages
SPIL: indicates overload resulting in a spill.
Message: Spill mode.
THRT: indicates overload resulting in a
throttle. Message: Throttle mode.
Extended Data
XXX: An integer value indicating the total
number of overload events that occurred during
the most recent alarm period.
OVL Alarm CLI Commands
To set Overload Alarm time window:
HP SA7120> set ovl_window
65000, default: 15)
To display Overload Alarm time window:
HP SA7120> show ovl_window
Examples:
HP SA7120> set ovl_window 10
HP SA7120> show ovl_window
Check for overload conditions [sec]: 10
NLS: Network
Link Status
Alarm
An alarm is issued whenever the Network or Server link status is
changed.
Format:
A:mm/dd/yyyy hh:mm:ss
NLS:NETL|SVRL:LNKD|10HDX|10FDX|100HDX|100FDX:/
*message*/
Where:
A: identifies the message as an alarm.
mm/dd/yyyy hh:mm:ss is the timestamp.
NLS: identifies the message as a Network Link
Status Alarm.
Alarm Modifiers and Messages
NETL: indicates the network port status.
Message: [No carrier|10Mb/s|100Mb/s][half
duplex|full duplex]
SVRL indicates the server port status. Message:
[No carrier|10Mb/s|100Mb/s] [half duplex|full
duplex]