C H A P T E R 7 HP e-Commerce Server Accelerator SA7100/SA7120 User Guide
116
UTL Alarm CLI commands
To set Utilization Threshold Alarm time window:
set utl_window
default: 15)
To set Utilization Threshold Alarm high-water value:
set utl_highwater
default: 90)
To set Utilization Threshold Alarm low-water value:
set utl_lowwater
default: 60)
To display current settings:
show utl_window
show utl_highwater
show utl_lowwater
Examples:
HP SA7120> set utl_window 10
HP SA7120> show utl_window
Utilization Window set [secs]: 10
HP SA7120> set utl_highwater 80
HP SA7120> show utl_highwater
Utilization High water mark [%]: 80
HP SA7120> set utl_lowwater 60
HP SA7120> show utl_lowwater
Utilization Low water mark [%]: 60
OVL: Overload
Alarm
WARNING: This alarm
indicates loss of encryp-
tion/decryption. (Normal
SSL operation resumes
when the alarm ceases.)
When enabled, an alarm is issued upon occurence of overloads
resulting in spills or throttles during the current user-configured
alarm period (5 to 65000 seconds, default: 15 seconds).
Format:
A:mm/dd/yyyy hh:mm:ss
OVL:SPIL|THRT:XXX:
/*message*/
Where:
A: identifies the message as an alarm.
mm/dd/yyyy hh:mm:ss is the timestamp.
OVL: identifies the message as an Overload
Alarm.