Replacing the failed component, Replacement instructions – HP 6400.8400 Enterprise Virtual Array User Manual
Page 79

Replacing the failed component
CAUTION:
Components can be damaged by electrostatic discharge. Use proper anti-static
protection.
•
Always transport and store CRUs in an ESD protective enclosure.
•
Do not remove the CRU from the ESD protective enclosure until you are ready to install it.
•
Always use ESD precautions, such as a wrist strap, heel straps on conductive flooring, and
an ESD protective smock when handling ESD sensitive equipment.
•
Avoid touching the CRU connector pins, leads, or circuitry.
•
Do not place ESD generating material such as paper or non anti-static (pink) plastic in an ESD
protective enclosure with ESD sensitive equipment.
•
HP recommends waiting until periods of low storage system activity to replace a component.
•
When replacing components at the rear of the rack, cabling may obstruct access to the
component. Carefully move any cables out of the way to avoid loosening any connections.
In particular, avoid cable damage that may be caused by:
◦
Kinking or bending.
◦
Disconnecting cables without capping. If uncapped, cable performance may be impaired
by contact with dust, metal or other surfaces.
◦
Placing removed cables on the floor or other surfaces, where they may be walked on or
otherwise compressed.
Replacement instructions
Printed instructions are shipped with the replacement part. Instructions for all replaceable components
are also included on the documentation CD that ships with the EVA6400/8400 and posted on
the web. For the latest information, HP recommends that you obtain the instructions from the web.
Go to the following website:
Storage Systems, then select HP 6400/8400 Enterprise Virtual Arrays under P6000/EVA Disk
Arrays. The manuals page for the EVA6400/8400 appears. Scroll to the Service and maintenance
information section where the replacement instructions are posted.
•
HP controller enclosure replacement instructions
•
HP cache battery replacement instructions
•
HP controller blower replacement instructions
•
HP power supply replacement instructions
•
HP operator control panel replacement instructions
•
HP disk enclosure backplane replacement instructions
•
HP disk enclosure fan module replacement instructions
•
HP disk enclosure front UID interconnect board (with cable) replacement instructions
•
HP disk enclosure front UID replacement instructions
•
HP disk enclosure I/O module replacement instructions
•
HP disk enclosure midplane replacement instructions
•
HP disk enclosure power supply replacement instructions
Replacing the failed component
79