I/o modules, I/o module status indicators – HP 6400.8400 Enterprise Virtual Array User Manual
Page 10
![background image](/manuals/398934/10/background.png)
Figure 3 Disk enclosure rear view
7. I/O module B
1. Power supply 1
8. Rear UID push button
2. Power supply 1 status LED
9. Enclosure status LEDs
3. Fan 1
10. Fan 2
4. Enclosure product number and serial number
11. Power push button
5. Fan 1 status LED
12. Power supply 2
6. I/O module A
I/O modules
Two I/O modules provide the interface between the disk enclosure and the host controllers,
(
). For redundancy, only dual-controller, dual-loop operation is supported. Each
controller is connected to both I/O modules in the disk enclosure.
Each I/O module has two ports that can transmit and receive data for bidirectional operation.
Activating a port requires connecting a Fibre Channel cable to the port. The port function depends
upon the loop.
Figure 4 I/O module detail
4. Manufacturing diagnostic port
1. Double 7–segment display: enclosure ID
5. I/O module status LEDs
2. 4 Gb I/O ports
3. Port 1 (P1), Port 2 (P2) status LEDs
I/O module status indicators
There are five status indicators on the I/O module. See
. The status indicator
states for an operational I/O module are shown in
.
shows
the status indicator states for a non-operational I/O module.
10