Table 33 Multiple selected target parameters (not supported for Custom Command Tools)
Description
Parameter
Repeated pattern (only repeats if a current selection exists).
If a current target selection does not exist, the text between
%( ... %)
the delimiters is removed on expansion. This allows the
text to be optional and dependent upon the target selection
list.
Selection index (one-based).
%i
Do not substitute anything, but increment the selection index
to the next integer and the referenced target system to the
next target in the selected target list.
%z
Encrypted text (encrypt after all other parameters have
been substituted).
% < ... % >
Enables you to retain a % in the command/URL after
substitution.
%%
NOTE:
For more information about parameterized strings, refer to the HP SIM online help.
Common tool attributes
Common name values available to use for TDEFs.
Table 34 Task Wizard names values
Description
Names values
Displays command line equivalent of GUI action.
show-cmdline
Values: True | False (default: true)
Value is a string giving relative path to jsp page that should
be displayed, where n = sequential value starting at 1.
Custom-page-n
Limits the types of selections available for choosing to only
System Lists or only Event Lists. If this value is not present
then both System and Events lists are available.
ListType
Values: systemLists | eventLists
Limits the type of selections allowed for the tool. If "list",
then only lists (criteria) are allowed for selection. If
SelectionType
"collection", then only collections (non-criteria) are allowed
for selection. If "individual", then only individual systems
are allowed for selection.
Values: list | individual | collection
This informs the task wizard that the selections made for
this tool are the actual events and not the systems from
Targets-are-events
which the events were generated, which is the default
behavior. When using this attribute, the task wizard will
assume a "listType" of "eventLists" and a
"selectionType" of "list".
By default, the task wizard displays the target selection
page as the first page during task creation. When a tool
PageIndex
defines its own custom parameter pages, they may instruct
the task wizard where to place the target selection page.
n = value starting at 1.
A tool may wish to show the target selection page without
allowing the user to change the target.
TargetSelection lockTargetSelection
Values: true | false (default: false)
228 Custom tool definition files