beautypg.com

HP XP Business Copy Software User Manual

Page 96

background image

Table 37 CESTPAIR Command Parameters (Adding Pairs)

Description

Value

Parameter

Device number.

DEVN

If you set a parameter other than the
parameters on the left, the command will be
rejected.

Primary volume (S-VOL): SSID, serial number,
channel connection address, and CU number.

1

You must set MSF00 instead of a serial number
to request the Add and Split operation. This
parameter is valid for MODE(COPY) or
MODE(NOCOPY) only.

You must set MAnn0 instead of a serial number
if you create SIz pairs in a CTG with ID nn.

PRIM

Secondary volume (T-VOL): SSID, serial
number, channel connection address, and CU
number.

1

SEC

When you perform CESTPAIR command on
SIz, no matter whether you specify COPY or
NOCOPY for the MODE parameter, the
storage system recognizes it as COPY mode.
Therefore, initial full-volume copy will be
performed.

COPY

MODE

NOCOPY

Copy speed will be slow, except when the DKC
emulation type is 2105 or 2107. When the
DKC emulation type is 2105 or 2107, the
copy speed is always medium regardless what
you specify for the PACE parameter.

1

PACE

Copy speed will be medium.

other than 1

SIz does not use this parameter. SIz ignores it.

Not applicable.

CRIT

MSGREQ function is applicable.

Note that you cannot use the MSGREQ function
when the Add and Split operation is required.
If you specify YES for this parameter when the
Add and Split operation is required, the
command will be rejected and end abnormally
by reporting CC = 8.

YES

MSGREQ

MSGREQ function is not applicable.

NO

Pair create operation will be performed
whether the T-VOL is online or not.

YES

ONLINSEC

2, 3

Pair create operation will not be performed if
the T-VOL is online.

NO

1

CU number is valid only for the DKC emulation type 2105 or 2107.

2

When you do not specify the parameter, the result is same as when you specify NO for this parameter.

3

The ONLINSEC parameter is valid only for the DKC emulation type 2105 or 2107.

If you specify NOCOPY for the MODE parameter and YES for the MSGREQ parameter, the
CESTPAIR command will end before the copying operation is completed.

Figure 40 (page 96)

shows an example of the CESTPAIR command.

Figure 40 CESTPAIR Command

CESTPAIR DEVN (X

DE80

) PRIM (X

0080

,30158,X

00

) SEC (X

0080

,30158,X

01

)

MODE (COPY) PACE (15)

96

Performing ShadowImage for Mainframe Pair Operations Using PPRC

This manual is related to the following products: