Table 24 History Window
Description
Item
Allows you to return to the previous page of the list. This button is selectable only when
the number of operation histories in the storage system exceeds 16,384, which is the
maximum number of histories that can be displayed on one page. The button is grayed
out if the total number of operation histories in the storage system is less than 16,384.
Previous button
Allows you to turn to the next page of the list. This button is selectable only when the
number of operation histories in the storage system exceeds 16,384 volumes, which is
the maximum number of histories that can be displayed on one page. The button is
grayed out if the total number of operation histories in the storage system is less than
16,384.
Next button
Displays the date and time (YYYY/MM/DD hour/min/sec) when a SIz pair or volume
operation has been performed.
Date
Displays the LDKC:CU:LDEV of the S-VOLs used for pair operation in the past.
S-VOL
Displays the LDKC:CU:LDEV of the T-VOLs used for pair operation in the past.
T-VOL
Displays the reference codes of ShadowImage for Mainframe.
Code
Displays the messages to inform the conditions of the past SIz pair. For details about the
messages, see
.
Message
Table 25 ShadowImage for Mainframe Status & History Reference Codes and Messages
Description
Message
Code
The SIz initial copy operation started.
DUPLEX START
4710
The SIz initial copy operation ended, and the
pair status changed to Duplex.
DUPLEX END
4720
The SIz split operation started.
SPLIT START
4730
The SIz split operation ended, and the pair
status changed to Split.
SPLIT END
4740
The SIz resync operation started.
RESYNC START
RESYNC-R START
4750
The SIz resync operation ended, and the pair
status changed to Duplex.
RESYNC END
RESYNC-R END
4760
The SIz pair is deleted, and the pair status
changed to Simplex.
PAIR DELETE
4780
The SIz pair suspended, and the pair status
changed to Suspend.
PAIR SUSPEND
4790
A copy ended abnormally (reason other than
above).
PENDING ABNORMAL END
47D0
Initialization started.
INITIALIZE START
47E9
Initialization ended normally.
INITIALIZE END
47EA
Initialization ended abnormally.
INITIALIZE ENDED ABNORMAL
47EB
Option Window
You can set options for ShadowImage for Mainframe in the Option window (see
). For detailed information about how to set options, see
Option Window
59