Cquery – HP XP Business Copy Software User Manual
Page 106
Table 47 Contents that Display when Issuing the CQUERY or the QUERY Command on SIz Pairs
Content
Item
Device number of the volume on which the CQUERY command is issued.
DEVICE
PRIMARY indicates that the volume is an S-VOL.
SECONDARY indicates that the volume is a T-VOL.
LEVEL
Pair status.
STATE
Since this item is invalid for SIz pairs, ACTIVE is always displayed.
PATH STATUS
Since this item is invalid for SIz pairs, NO is always displayed.
CRIT
Since this item is invalid for SIz pairs, NO is always displayed.
CGRPLB
SSID of the CU where the S-VOL belongs.
PRIMARY-SSID
LDEV number of the S-VOL.
PRIMARY-CCA
CU number of the S-VOL.
PRIMARY-LSS
Serial number of the S-VOL.
PRIMARY-SERIAL
SSID of the CU where the T-VOL belongs.
SECONDARY-SSID
LDEV number of the T-VOL.
SECONDARY-CCA
CU number of the T-VOL.
SECONDARY-LSS
Serial number of the T-VOL. If you perform the CQUERY TSO command for the
T-VOL, the following information is displayed as well as the serial number of
the T-VOL.
00ab000nnnnn
a:
•
S: This pair is defined as a CTG.
•
0: Other than listed above.
b:
•
@: This pair was split by using the At-Time Split function.
•
0: Other than listed above.
nnnnn
: Serial number of the T-VOL.
SECONDARY-SERIAL
Since this item is invalid for SIz pairs, 1 is always displayed.
1
PATHS
Since this item is invalid for SIz pairs, FFFF FFFF is always displayed.
1
SAID DEST STATUS
Since this item is invalid for SIz pairs, PATH ESTABLISH is always displayed.
1
DESCRIPTION
Since this item is invalid for SIz pairs, 100% is always displayed.
1
PERCENT OF COPY COMPLETE
Since this item is invalid for SIz pairs, the content of this item is also invalid.
SUBSYSTEM
Since this item is invalid for SIz pairs, the content of this item is also invalid.
WWN
Since this item is invalid for SIz pairs, the content of this item is also invalid.
LIC LEVEL
1
When the MCU-RCU path for TCz is created on the CU where the SIz pair is created, the information about the
MCU-RCU path will be displayed. For detailed information about the MCU-RCU path, see the HP StorageWorks
XP24000/XP20000 Continuous Access Software User's Guide.
CQUERY
lists and describes the CQUERY command parameters that can be used when
you see the status of SIz pairs.
106 Performing ShadowImage for Mainframe Pair Operations Using PPRC