Stalled – HP XP P9500 Storage User Manual
Page 55
•
If the confirmed user SVC version is old and does not satisfy conditions for the prerequisite user
SVC version requirement of Smart Manager for Mainframe:
Use Business Continuity Manager to delete the user SVC, and then use Smart Manager for Main-
frame to register it again.
•
If the confirmed user SVC version satisfies conditions for the prerequisite user SVC version:
You can use the currently enabled user SVC as it is.
TIP:
•
For details on the
YKINSCHK
command, see the
HP XP P9000 for Business Continuity Manager
Software Reference Guide.
•
For details on how to delete the user SVC in Business Continuity Manager, see the
HP XP P9000
for Business Continuity Manager Software Installation Guide.
•
This procedure lets you install Smart Manager for Mainframe for the first time. If you need to up-
grade Smart Manager for Mainframe, refer to the instructions for preparing for the upgrade.
Related topics
• Prerequisite user SVC versions for Smart Manager for Mainframe
• Preparation for version updating
Notes on setting environment variables or system symbols if Business Continuity
Manager is installed
Smart Manager for Mainframe and Business Continuity Manager use the same environment variables
and system symbols. Therefore, it is recommended that you keep the currently enabled operating
environment setting values (that is, environment variables or values set to system symbols) unchanged
in the system where Business Continuity Manager is running. In particular, if you change the prefix
of a license information dataset, you must register the Business Continuity Manager license again
because the license information dataset is shared by Smart Manager for Mainframe and Business
Continuity Manager. Change the operating environment setting values very carefully if you need to
change them.
TIP:
To check the currently enabled operating environment setting values, do the following:
•
If Smart Manager for Mainframe has already been installed (when you upgrade it)
Check the operating environment setting values that were obtained when preparing for the upgrade.
•
If Smart Manager for Mainframe has not been installed (when you install it for the first time)
Use the
YKDSPENV
command to do the check. For details on the
YKDSPENV
command, see the
HP XP P9000 for Business Continuity Manager Software Reference Guide.
Related topics
• Setting the operating environment for Smart Manager for Mainframe (setting environment variables
User Guide