HP XP P9500 Storage User Manual
Page 149

Use the IXCMIAPU utility with the
DELETE LOGSTREAM NAME(log_stream_name)
parameter
specified to delete the log stream. The log dataset is deleted when the log stream is deleted. For
details, see the manual
MVS Setting Up a Sysplex
.
Related topics
• Parameters specified when a log stream is defined
• JCL example for deleting a log stream
Re-defining the log stream when the event log is full
If a log dataset is full, execution of CLI commands will continue, but event log data will no longer be
output. To resume the output of event log data, suspend the CLI command, and then delete and
re-define the log stream.
1.
Suspend the CLI command.
2.
Use the event log data output tool (
KTLOGCP
) to output all log data from the log stream to a
dataset.
3.
Use the IXCMIAPU utility with the
DELETE LOGSTREAM NAME(log_stream_name)
parameter
specified to delete the log stream.
The log dataset is deleted when the log stream is deleted. For details, see the manual MVS Setting
Up a Sysplex.
4.
Re-define the log stream.
5.
Log on to TSO/E again and then execute the CLI command.
Related topics
• Parameters specified when a log stream is defined
• Outputting logs by using the event log data output tool
• JCL example for deleting a log stream
Restarting the system logger service and re-defining the log stream when the
event log is full
If a log dataset is full, execution of CLI commands will continue, but event log data will no longer be
output. The log stream cannot be deleted during execution of a CLI command. Therefore, if the CLI
command cannot be stopped when a log dataset is full, you can restart the system logger service and
then delete and re-define the log stream to resume the output of event log data.
1.
Enter the
FORCE IXGLOGR,ARM
command to stop the system logger service.
2.
Enter the
S IXGLOGRS
command to restart the system logger service.
3.
Use the IXCMIAPU utility with the
DELETE LOGSTREAM NAME(log_stream_name)
parameter
specified to delete the log stream.
The log dataset is deleted when the log stream is deleted. For details, see the manual MVS Setting
Up a Sysplex.
4.
Re-define the log stream.
User Guide