Log types for smart manager for mainframe, Collecting event logs, 142 collecting event logs – HP XP P9500 Storage User Manual
Page 142: Related topics
1.
Log on to the TSO/E terminal.
2.
Enter the following commands.
• To output an ABEND dump to the spool:
ALLOC DD(SYSABEND) SYSOUT(SYSOUT-class)
• To output an ABEND dump to a dataset:
ALLOC DD(SYSABEND) DS(dataset-name)
3.
Execute a CLI command.
4.
If the CLI command terminated abnormally and the system returned to the READY mode, press
the Enter key.
If you enter a TSO/E command without pressing the Enter key, ABEND dumps might not be
output.
Log types for Smart Manager for Mainframe
Of the acquired trace information, only the information that must be presented to the user is output
to a log.
The following table shows the log types for Smart Manager for Mainframe, the collected information,
and the output destinations.
Table 51 Log types for Smart Manager for Mainframe
Output destination
Collected information
Log type
•
When the system logger service is used:
DASD-only log stream for the system logger ser-
vice
•
When the system logger service is not used:
Log dataset for Smart Manager for Mainframe
•
Messages
•
Only in the case of an I/O error, parameter
information, return information, and sense byte
information for that I/O
•
Time-stamps
•
Command parameter information
Event log
ISPF log dataset
•
Transaction logs in the ISPF panel
•
Messages that were output during command
execution
ISPF log
SYSLOG
•
CLI command name
•
Parameters
•
Execution results
CLI command-execution
log
Related topics
• Collecting the CLI command-execution log
Collecting event logs
This section describes how to collect event logs.
Collecting trace information and logs
142