Sun storagetek 2540, Sun storagetek v2x2, Emc clariion cx series – HP XP External Storage Software User Manual
Page 148: Notes on connecting an emc clariion cx series

Table 50 System Parameter (Sun StorageTek FlexLine 380)
Parameter Setting
Parameter
Windows Non-clustered (DMP Support)
host type
Sun StorageTek 2540
When connecting a Sun StorageTek 2540 as an external storage system, set the system parameters
of the Sun StorageTek 2540 according to
. For the system parameters that are
not in
, see the documentation for the Sun StorageTek 2540 and set the
parameters appropriately for the connecting configuration.
Table 51 System Parameter (Sun StorageTek 2540)
Parameter Setting
Parameter
Windows 2K non Clustered DMP
host type
Sun StorageTek V2X2
When connecting a Sun StorageTek V2X2 as an external storage system, make sure that only one
cross-subsystem path is configured when you map external volumes. Do not add any alternate
paths after you finish mapping external volumes.
EMC CLARiiON CX Series
When you connect an EMC CLARiiON CX series as an external storage system, set the system
parameters of the EMC CLARiiON CX series according to the settings in
. For
system parameters that are not in
, see the EMC CLARiiON CX series
documentation and set the parameters appropriately to connect your configuration.
Table 52 System Parameters (EMC CLARiiON CX series)
Parameter Setting
Parameter
CLARiiON Open
Initiator Type
2
Failover Mode
Notes on Connecting an EMC CLARiiON CX Series
Volumes created with Individual Disk Units (JBOD disks) of EMC CLARiiON CX series are not
supported.
The following restrictions are for the use of the RAID-6 volume for the EMC CLARiiON CX series.
Moreover, when you downgrade a version of a storage system that does not support the RAID-6
volume from a version of a storage system that supports the RAID-6 volume, the configuration of
the EMC CLARiiON CX series should be changed.
148
Connecting External Storage Systems