Behavior of the alternate path, Sun storedge 6120/6320, Sun storagetek flexline 380 – HP XP External Storage Software User Manual

Page 147: Sun storedge 6120/6320 sun storagetek flexline 380

background image

In the configuration in

Figure 44 (page 147)

, you can identify the logical volumes referring to

Characteristic2 in the XP External Storage windows. The first 32 characters of Characteristic2
indicate the World Wide LUN Name that can be found on the EVA storage system side. You can
identify the logical volume of the EVA storage system by this World Wide LUN Name.

Figure 44 Configuration Example for which Logical Volumes Cannot be Identified only by
Characteristic

Behavior of the Alternate Path

When an EVA storage system is connected, the behavior of the alternate path differs depending
on the microcode version of the EVA storage system.
If the subsystem system type is EVA3000/5000, the behavior of the alternate path differs between
the EVA storage system of the microcode version 4.000 or later and the EVA storage systems of
the earlier microcode versions.
To replace the microcode of the EVA storage system, check whether the behavior of the alternate
path changes as a result of changing the microcode version. If the behavior of the alternate path
changes, perform the Delete Volume operation of XP External Storage to release the setting of
mapping the EVA storage system volume before you actually replace the microcode.
See the EVA storage system manuals for how the behavior of the alternate path changes.

Sun StorEdge 6120/6320

When connecting a Sun StorEdge 6120/6320 as an external storage system, set the system
parameters of the Sun StorEdge 6120/6320 according to

Table 49 (page 147)

. For the system

parameters that are not in

Table 49 (page 147)

, see the documentation for the Sun StorEdge

6120/6320 and set the parameters appropriately for the connecting configuration.

Table 49 System Parameter (Connecting Sun StorEdge 6120/6320)

Parameter Setting

Parameter

SUN

port host

Sun StorageTek FlexLine 380

When you connect a Sun StorageTek FlexLine 380 as an external storage system, set the system
parameters of the Sun StorageTek FlexLine 380 according to

Table 50 (page 148)

. For the system

parameters that are not in

Table 50 (page 148)

, see the documentation for the Sun StorageTek

FlexLine 380 and set the parameters appropriately for the connecting configuration.

Sun StorEdge 6120/6320

147