Igmp – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual
Page 30

Command line 30
Item Description
->show firmware
Displays current version of the firmware
->show firmware *
Displays detailed listing of all firmware
Item Description
update firmware
Update the firmware on all Virtual Connect modules in the domain.
Syntax
update firmware [-quiet] URL=
Parameter
quiet
Suppresses progress messages and displays only SUCCESS and FAILURE messages
Option
URL (required)
The location and name of the firmware image to use for the update. The default
protocol to use is HTTP.
Example
->update firmware url=http://www.myserver.com/fw/vc-1.20.rom
Updates the firmware on all Virtual Connect modules in the domain
->update firmware -quiet
URL=http://www.someserver.com/firmware/vc-1.20.rom
Updates firmware using the -quiet option
igmp
Manage Ethernet IGMP Snooping settings.
Supported actions: help, set, show
Item Description
set igmp
Modify Ethernet IGMP Snooping settings.
Syntax
set igmp [Enabled=
Properties
Enabled
(optional)
Enables or disables IGMP Snooping. Valid values include "true" and "false".
Timeout
(optional)
The idle timeout interval (in seconds) for IGMP Snooping. Valid values include
integers from 1-3600. The default IGMP idle timeout is 260 seconds.
Examples
->set igmp Enabled=true
Enables IGMP Snooping
->set igmp Enabled=true Timeout=30
Enables IGMP Snooping and sets the idle timeout
Item Description
show igmp
Display Ethernet IGMP Snooping settings.
Syntax
show igmp