beautypg.com

Fan problems, General fan problems are occurring, Hard drive problems – HP ProLiant ML110 G2 Server User Manual

Page 79: System completes post but hard drive fails

background image

Troubleshooting 79

Be sure the maximum number of drives per controller has not been exceeded. Refer to the controller

documentation to determine the capacity of the controller.

NOTE:

It is recommended that no more than two DLT drives per bus exist.

If using an external DLT drive that requires a SCSI terminator to be secured to the unused SCSI IN

connector on the back of the drive, be sure the SCSI terminator is connected.
DLT drives can be daisy chained, but do not connect more than three units per SCSI controller. The last
DLT drive in the chain requires the SCSI terminator.

Check cables for damaged or bent connectors.

An error occurs during backup, but the backup is completed

Action: Contact the software vendor for more information about the message. If the error does not disrupt the

backup, you may be able to ignore the error.

Fan problems

General fan problems are occurring

Action:

1.

Be sure the fans are properly seated and working.

a.

Follow the procedures and warnings in the server documentation for removing the access panels
and accessing and replacing fans.

b.

Unseat, and then reseat, each fan according to the proper procedures.

c.

Replace the access panels, and then attempt to restart the server.

2.

Be sure the fan configuration meets the functional requirements of the server. Refer to the server
documentation.

3.

Be sure no ventilation problems exist. If you have been operating the server for an extended period of
time with the access panel removed, airflow may have been impeded, causing thermal damage to

components. Refer to the server documentation for further requirements.

4.

Be sure no POST error messages are displayed while booting the server that indicate temperature

violation or fan failure information. Refer to the server documentation for the temperature requirements
for the server.

5.

Replace any required non-functioning fans and restart the server. Refer to the server documentation for
specifications on fan requirements.

6.

Be sure all fan slots have fans or blanks installed. Refer to the server documentation for requirements.

7.

Verify the fan airflow path is not blocked by cables or other material.

Hard drive problems

System completes POST but hard drive fails

Action:

1.

Be sure no loose connections (on page

58

) exist.

2.

Be sure no device conflict exists.