beautypg.com

Hot-plug scsi hard drive led combinations, Sas and sata hard drive led combinations, Sas and sata – HP ProLiant ML110 G2 Server User Manual

Page 60: Hard drive led combinations

background image

Troubleshooting 60

If only one SCSI hard drive is used, install it in the bay with the lowest number.

Drives must be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.

Hot-plug SCSI hard drive LED combinations

Activity
LED (1)

Online
LED (2)

Fault LED
(3)

Interpretation

On, off, or

flashing

On or off Flashing

A predictive failure alert has been received for this drive.

Replace the drive as soon as possible.

On, off, or
flashing

On

Off

The drive is online and is configured as part of an array.
If the array is configured for fault tolerance and all other drives in the

array are online, and a predictive failure alert is received or a drive

capacity upgrade is in progress, you may replace the drive online.

On or
flashing

Flashing

Off

Do not remove the drive. Removing a drive may terminate the current
operation and cause data loss.

The drive is rebuilding or undergoing capacity expansion.

On

Off

Off

Do not remove the drive.

The drive is being accessed, but (1) it is not configured as part of an

array; (2) it is a replacement drive and rebuild has not yet started; or
(3) it is spinning up during the POST sequence.

Flashing

Flashing

Flashing

Do not remove the drive. Removing a drive may cause data loss in

non-fault-tolerant configurations.

One or more of the following conditions may exist:

The drive is part of an array being selected by an array

configuration utility

Drive Identification has been selected in HP SIM

The drive firmware is being updated

Off

Off

On

The drive has been placed offline due to hard disk drive failure or
subsystem communication failure.

You may need to replace the drive.

Off

Off

Off

One or more of the following conditions may exist:

The drive is not configured as part of an array

The drive is configured as part of an array, but it is a replacement

drive that is not being accessed or being rebuilt yet

The drive is configured as an online spare

If the drive is connected to an array controller, you may replace the

drive online.

SAS and SATA hard drive LED combinations

NOTE:

Predictive failure alerts can occur only when the server is connected to a Smart Array

controller.

Online/activity

LED (green)

Fault/UID LED

(amber/blue)

Interpretation

On, off, or flashing Alternating amber

and blue

The drive has failed, or a predictive failure alert has been received
for this drive; it also has been selected by a management

application.